isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Relays and Modules - Transmission and Drivetrain > < Starter Relay|Locations
Page 1
background image

Starter Relay: Testing and Inspection

Normally-open type A:

1. Check for continuity between the terminals.

^

There should be continuity between the No. 1 and No. 3 terminals when power and ground are connected to the No. 2 and No. 4 terminals.

^

There should be no continuity between the No. 1 and No. 3 terminals when power is disconnected.

Starter Cut Relay

^

Starter cut relay

Relays and Modules - Transmission and Drivetrain > < Starter Relay|Locations