isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Sensors and Switches - Transmission and Drivetrain > < Shift Interlock Control Module|Drawing|Page 3167
Page 1
background image

Transmission Position Relay: Testing and Inspection

Normally-open type B:

1. Check for continuity between the terminals.

^

There should be continuity between the No. 1 and No. 2 terminals when power and ground are connected to the No. 3 and No. 4 terminals.

^

There should be no continuity between the No. 1 and No. 2 terminals when power is disconnected.

A/T reverse relay - Type 1

A/T reverse relay - Type 2