isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Starting System > < Voltage Regulator|Specifications
Page 1
background image

Voltage Regulator: Testing and Inspection

Fig. 7  IC regulator testing

    To perform regulator tests the following measuring instruments will be needed: resistor (10 ohms, 3 watts) R1, variable resistor (0-300 ohms,
12 watts), battery (12 volts, 2 pieces) BAT1, BAT2, DC voltmeter (0-50V/0.5).

1.

Connect instruments as shown in Fig. 7.

2.

Measure voltage at BAT1 to VI. Voltmeter reading should be 10-13 volts.

3.

Gradually increase resistance of the variable resistor from zero.

4.

Measure voltage between terminals ``E'' and ``F,'' noting voltage change from the VI terminal. If no change is noted, replace regulator.

5.

Measure voltage between intermediate tap on variable resistor and terminal ``E'' (V4) without actuating the variable resistor. Voltmeter should
read 14.0-14.6 volts, or regulator must be replaced.

Starting System > < Voltage Regulator|Specifications