Valve Cover: Service and Repair
Left Hand Side

REMOVAL

Preparation: Remove battery ground cable

1. Ignition wire

-

Disconnect from spark plug side.

2. Positive Crankcase Ventilation hose and Vacuum hose

-

Disconnect from common chamber.

-

Disconnect vacuum hose from throttle body.

3. Engine harness bracket

-

Remove fixing bolts on cylinder head cover.

4. Exhaust Gas Recirculation (EGR) pipe

-

Remove fixing bolts on cylinder head cover.

-

Remove two fixing bolts on exhaust manifold.

-

Remove flange nut on EGR valve pipe.

5. Cylinder head cover

-

Remove 11 fixing bolts then the cylinder head cover.

INSTALLATION