Rodeo (4WD) V6-3165cc 3.2L SOHC (6VD1) (1993)
Blower Motor: Testing and Inspection
BLOWER MOTOR
1. Disconnect the 2P (B-4) connector from the blower motor.
2. Connect the battery positive terminal to the No. 1 terminal of the blower motor and negative to the No. 2.
3. Be sure to check to see if the blower motor operates correctly.