isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Heater Core > < Expansion Valve|Service and Repair
Page 2
background image

-

Slit the case parting face with a knife since the lining is separated when removing the evaporator.

-

Lift to remove the upper case.

6. Evaporator core
7. Expansion valve

-

Tear off the insulator carefully.

-

Remove the sensor fixing clip.

-

Use a back-up wrench when disconnecting all refrigerant pipes.

INSTALLATION

To install, follow the removal steps in the reverse order, noting the following points:

1. O-rings cannot be reused. Always replace with new ones.
2. Be sure to apply new compressor oil to the O-rings when connecting lines.
3. Be sure to install the sensor and the insulator in their previous positions.
4. To install a new evaporator core, add 50 cc (1.7 ft.oz.) of new compressor oil to a new core.
5. Tighten the refrigerant lines to the specified torque.
6. Apply an adhesive to parting face of lining when assembly evaporator assembly.

Heater Core > < Expansion Valve|Service and Repair