Refrigerant Pressure Sensor / Switch: Specifications

PRESSURE SWITCH..................................................................................................................................................................Type Dual pressure switch
.................................................................................................................................................................................................................Low pressure control
...................................................................................................................................................................................- ON: 205.9 ± 29.4 kPa (29.9 ± 4.3 psi)
.................................................................................................................................................................................- OFF: 176.5 ± 24.5 kPa (25.6 ± 3.6 psi)

................................................................................................................................................................................................................High pressure control
...........................................................................................................................................................................- ON: 2353.6 ± 196.1 kPa (341.3 ± 28.4 psi)
........................................................................................................................................................................- OFF: 2942.0 ± 196.1 kPa (426.6 ± 28.4 psi) 

..............................................................................................................................................................................................Triple pressure switch (V6, A/T)

.................................................................................................................................................................................................................Low pressure control
...................................................................................................................................................................................- ON: 196.3 ± 29.4 kPa (27.0 ± 4.3 psi)
.................................................................................................................................................................................- OFF: 176.5 ± 19.6 kPa (25.6 ± 2.8 psi)

...........................................................................................................................................................................................................Medium pressure control
.............................................................................................................................................................................- ON: 1471.0 ± 98.1 kPa (213.3 ± 14.2 psi)
.........................................................................................................................................................................- OFF: 1078.7 ± 117.7 kPa (156.4 ± 17.7 psi)

................................................................................................................................................................................................................High pressure control