isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Generator <--> [Alternator]|Removal and Installation|Page 3524 > < Regulated Voltage|Page 3521
Page 1
background image

Generator: Service and Repair
Removal and Installation

REMOVAL

Preparation:

-

Battery ground cable

1. Fan belt

-

Loosen lock bolt.

-

Loosen adjust bolt.

2. Wheel and tire assembly, front right
3. Wiring connector

-

Disconnect terminal "B" and connector.

-

From generator, supporting generator assembly by hand.

4. Adjuster
5. Generator fixing bolt

-

Remove the fixing bolt.

6. Generator assembly

-

Take out generator upper side.

INSTALLATION

6. Generator assembly

-

Direct terminal "B" to bottom side and bring generator assembly to the position to be installed.

5. Generator fixing bolt
4. Adjuster
3. Wiring connector

-

Connect harness connector and direct terminal "B" to above side.

2. Wheel and tire assembly, front right
1. Fan belt

Generator <--> [Alternator]|Removal and Installation|Page 3524 > < Regulated Voltage|Page 3521