isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Condenser Fan > < Condenser HVAC|Locations|Page 6618
Page 2
background image

1. Install condenser assembly.

- If installing a new condenser, be sure to add 30 cc (1.0 fl.oz.) of new compressor oil to a new one.
- Tighten the condenser fixing bolts to the specified torque. 

Torque: 6 N.m (52 lb.in)

2. Connect refrigerant line.

- Tighten the inlet line connector fixing bolt to the specified torque.

Torque: 15 N.m (11 lb.ft)

- Tighten the outlet line connector fixing bolt to the specified torque.

Torque: 6 N.m (52 lb.in)

- O-rings cannot be reused. Always replace with new ones.
- Be sure to apply new compressor oil to the O-rings when connecting the refrigerant line.

3. Connect pressure switch connector.
4. Install engine hood lock.
5. Install engine hood front end stay.
6. Install radiator grille.

Condenser Fan > < Condenser HVAC|Locations|Page 6618