Refrigerant Pressure Sensor / Switch: Description and Operation
Triple Pressure Switch

TRIPLE PRESSURE SWITCH

Triple pressure switch is installed on the upper part of the receiver/drier. This switch is constructed  with a unitized type of two switches. 
One of them is a low and high pressure switch (Dual pressure switch) to switch "ON" or "OFF" the magnetic  clutch as a result of irregularly
high-pressure or low pressure of the refrigerant. The other one is a medium pressure switch (Cycling switch) to  switch "ON" or "OFF" the condenser
fan sensing the condenser high side pressure.