isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Starter Motor|Removal and Installation|Page 5439 > < Symptom Related Diagnostic Procedures|Page 5436
Page 1
background image

Starter Motor: Service and Repair
Removal and Installation

Removal

1. Battery ground cable.
2. Disconnect Heated O2 Sensor connector (1).

3. Remove exhaust front left pipe(2).
4. Remove heat protector(3).
5. Disconnect starter wiring connector from terminals "B" and "S"(4).
6. Remove starter assembly mounting bolts on inside and outside(5).

7. Remove starter assembly toward the bottom of engine(6).

Installation

1. Install starter assembly(6).
2. Install mounting bolts and tighten bolts to specified torque(S).

Torque: 40 N.m (30 lb.ft)

3. Reconnect the connectors to terminals "B" and "S" and tighten Terminals "B" to specified torque.

Torque: 9 N.m (80 lb.in)

Starter Motor|Removal and Installation|Page 5439 > < Symptom Related Diagnostic Procedures|Page 5436