isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Shift Indicator > < Malfunction Indicator Lamp - A/T|Locations|Page 4336
Page 2
background image

Abnormal

2. Indicator is flashing and the flash is 0.2 seconds ON and 0.2 seconds OFF always when ignition is on (engine cranked or not). This means that

there is a malfunction. Go To Displaying and Reading Trouble Codes 
See: Transmission Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Displaying and Reading Trouble
Codes

3. Indicator is staying ON always when Ignition is ON.

1. This means that connection between the lamp and the PCM is shorted to ground.
2. Verify if instrument panel terminal 6 of connector l-1 is shorted to ground.
3. Verity if the PCM connector C1 (RED) terminal A14 is shorted to ground.
4. Verify that the instrument panel terminal 12 of connector l-1 is connected to battery.
5. IF problem solved: GOTO CHECK TRANS INDICATOR.

NO:Replace Powertrain Control Module (PCM).

4. Indicator is staying OFF with the ignition ON (engine OFF).

1. This means that connection between the lamp and the PCM is shorted to battery or opened.
2. Verify if instrument panel terminal 6 of connector l-1 is shorted to battery or open.
3. Verify if the PCM connector C1 (RED) terminal A14 is shorted to battery or open.
4. Verify that the instrument panel terminal 12 of connector l-1 is connected to battery. If not, check the fuses and the connections (terminal 11 of

connector H-27) voltage.

5. IF problem solved: GOTO CHECK TRANS INDICATOR. 

NO: Replace Powertrain Control Module (PCM).