Page 2
background image

4. Place pre tensioned probe (6) of gauge on measuring arm of measuring device J-43038. The probe must be set precisely between the notch marks,

square to the plane surface (7).

5. Determine the left and right stops by turning the knurled bolt (2).

Set the dial of the gauge to zero.
Use the knurled bolt (2) to move the 2nd balancer shaft (exhaust side) back and forth. Again - simultaneously read off the tooth backlash from the
gauge.
The permissible tooth backlash is: 0.02 mm to 0.06 mm (0.0008 to 0.0024 inch).

6. The tooth backlash must be measured in 4 different positions - turn the crankshaft further at the fastening bolt of the timing belt drive gear by 45°

in the engine rotational direction until the measuring arm (2) is at "6 o'clock".