isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Condenser Fan > < Condenser HVAC|Locations|Page 4615
Page 2
background image

-

Tighten the condenser fixing bolts to the specified torque. 
Torque: 6 Nm (52 lb.in)

2. Connect refrigerant line. 

-

Tighten the inlet line connector fixing bolt to the specified torque. 
Torque: 15 Nm (11 lb.ft)

-

Tighten the outlet line connector fixing bolt to the specified torque. 
Torque: 6 Nm (52 lb.in)

-

O-rings cannot be reused. Always replace with new ones. 

-

Be sure to apply new compressor oil to the O-rings when connecting the refrigerant line. 

3. Connect pressure switch connector. 
4. Install engine hood lock. 
5. Install engine hood front end stay. 
6. Install radiator grille. 

Condenser Fan > < Condenser HVAC|Locations|Page 4615