isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 4747 > < Leak Check - Repair of Refrigerant Leaks|Page 4745
Page 1
background image

Refrigerant: Service and Repair
Refrigerant Recovery, Evacuating and Recharging

1.  Recovery

Air conditioning systems contain HFC-134a. This is a chemical mixture which requires special handling procedures to avoid personal injury.

-

Always wear safety goggles and protective gloves.

-

Always work in a well-ventilated area. Do not weld or steam clean on or near any vehicle-installed air conditioning lines or components.

-

If HFC-134a should come in contact with any part of the body, flush the exposed area with cold water and immediately seek medical help.

-

If it is necessary to transport or carry any container of HFC-134a in a vehicle, do not carry it in the passenger compartment.

-

If it is necessary to fill a small HFC-134a container from a large one, never fill the container completely. Space should always be allowed above
the liquid for expansion.

-

HFC-134a and R-12 should never be mixed as their compositions are not the same.

-

 HFC-134a PAG oil tends to absorb moisture more quickly than R-12 mineral oil and, therefore, should be handled more carefully.

-

 Keep HFC-134a containers stored below 40 °C (100 °F).

WARNING:

-

SHOULD HFC-134A CONTACT YOUR EYE(S), CONSULT A DOCTOR IMMEDIATELY.

-

DO NOT RUB THE AFFECTED EYE(S). INSTEAD, SPLASH QUANTITIES OF FRESH COLD WATER OVER THE AFFECTED
AREA TO GRADUALLY RAISE THE TEMPERATURE OF THE REFRIGERANT ABOVE THE FREEZING POINT.

-

OBTAIN PROPER MEDICAL TREATMENT AS SOON AS POSSIBLE. SHOULD THE HFC-134A TOUCH THE SKIN, THE
INJURY MUST BE TREATED THE SAME AS SKIN WHICH HAS BEEN FROSTBITTEN OR FROZEN.
 

Refrigerant Recovery 
The refrigerant must be discharged and recovered by using the J-39500 (ACR4:HFC-134a Refrigerant Recovery/Recycling/Recharging/System) or
equivalent before removing or mounting air conditioning parts.

1. Connect the high and low charging hoses of the ACR4 (or equivalent).
2. Recover the refrigerant by following the Manufacturer's Instructions.
3. When a part is removed, put a cap or a plug on the connecting portion so that dust, dirt or moisture cannot get into it.

Refrigerant Recycling 
Recycle the refrigerant recovered by J-39500 (ACR4:HFC-134a Refrigerant Recovery/Recycling/Recharging/System) or equivalent.
For the details of the actual operation, follow the steps in the ACR4 (or equivalent) Manufacturer's Instructions.

2.  Evacuating

Leak Check - Repair of Refrigerant Leaks|Page 4747 > < Leak Check - Repair of Refrigerant Leaks|Page 4745