isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 917 > < Leak Check - Repair of Refrigerant Leaks|Page 915
Page 3
background image

-

ACR4 (or equivalent) Method
For the charging of refrigerant recovered by ACR4 (or equivalent), follow the manufacturer's instruction.

-

Direct charging with a weight scale charging station method
1. Make sure the evacuation process is correctly completed.
2. Connect the center hose of the manifold gauge to the weight scale.
3. Connect the low pressure charging hose of the manifold gauge to the low pressure side service valve of the vehicle.
4. Connect the high pressure charging hose of the manifold gauge to the high pressure side service valve of the vehicle.

Leak Check - Repair of Refrigerant Leaks|Page 917 > < Leak Check - Repair of Refrigerant Leaks|Page 915