isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Technician Safety Information|Page 816 > < Technician Safety Information|Page 814
Page 1
background image

Hose/Line HVAC: Description and Operation

Restriction in the refrigerant line will be indicated by:

1. Suction line - A restricted suction line will cause low suction pressure at the compressor, low discharge pressure and little or no cooling. 
2. Discharge line - A restriction in the discharge line generally will cause the discharge line to leak. 
3. Liquid line - A liquid line restriction will be evidenced by low discharge and suction pressure and insufficient cooling. 

Refrigerant flexible hoses that have a low permeability to refrigerant and moisture are used.  These low permeability hoses have a special nylon layer on
the inside. 