isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Fuel Control Heated Oxygen Sensors|Page 2129 > < Manifold Absolute Pressure Sensor <--> [Manifold Pressure/Vacuum Sensor]|Description and Operation|Page 2124
Page 1
background image

Oxygen Sensor: Description and Operation
Fuel Control Heated Oxygen Sensors

Fuel Control Heated Oxygen Sensor (Pre-Catalyst)

The fuel control heated oxygen sensor (Bank 1 HO2S 1) is mounted in the exhaust stream where it can monitor the oxygen content of the exhaust gas.
The oxygen present in the exhaust gas reacts with the sensor to produce a voltage output. This voltage should constantly fluctuate from approximately 
100 mV to 900 mV.

The heated oxygen sensor voltage can be monitored with a Scan Tool. By monitoring the voltage output of the oxygen sensor, the PCM calculates the
pulse width command for the injectors to produce the proper combustion chamber mixture.

-

Low HO2S voltage is a lean mixture which will result in a rich command to compensate.

-

High HO2S voltage is a rich mixture which will result in a lean command to compensate.

Fuel Control Heated Oxygen Sensors|Page 2129 > < Manifold Absolute Pressure Sensor <--> [Manifold Pressure/Vacuum Sensor]|Description and Operation|Page 2124