d. Connect multimeter (resistance mode) to terminals 1 (E) and 4(H) on mode switch connector.
e. Loosen two mounting screws.
f.

Rotate mode switch slightly in both directions to determine the range (approx. 5 degrees) of electrical contact.

g. Position mode switch in middle of contact range.
h. Tighten two mounting screws.
i.

Remove multimeter and install mode switch harness connector with bracket to the transmission case.

j.

Connect transmission harness connector to mode switch connector.