Generator: Service and Repair
Removal and Installation

Removal

1. Disconnect battery ground cable. 
2. Move drive belt tensioner to loose side using wrench then remove drive belt. 
3. Disconnect terminal B wiring connector and connector. 

4. Remove generator bracket (1), (2) and remove generator assembly. 

Installation

1. Install generator assembly and bring generator assembly to the position to be installed. 