Handle with care to prevent damaging the condenser or radiator fin.

INSTALLATION

1. Install condenser assembly.

-

If installing a new condenser, be sure to add 30 cc (1.0 fl.oz.) of new compressor oil to a new one.

-

Tighten the condenser fixing bolts to the specified torque.
Torque: 6 N.m (52 lb.in)

2. Connect refrigerant line.

-

Tighten the inlet line connector fixing bolt to the specified torque.
Torque: 15 N.m (11 lb.ft)

-

Tighten the outlet line connector fixing bolt to the specified torque.
Torque: 6 N.m (52 lb.in)

-

O-rings cannot be reused. Always replace with new ones.

-

Be sure to apply new compressor oil to the O-rings when connecting the refrigerant line.

3. Connect pressure switch connector.
4. Install engine hood lock.
5. Install engine hood front end stay.
6. Install radiator grille.