Throttle Body: Service and Repair

REMOVAL PROCEDURE

1. Disconnect the negative battery cable.
2. Drain the cooling system. Refer to Engine Cooling section.

3. Disconnect the electrical connectors:

-

Throttle position (TP) sensor.

-

Intake air temperature (IAT) sensor. Refer to Intake Air Temperature Sensor in this section.

4. Disconnect the vacuum hose below the air horn.
5. Remove the intake air duct clamp.
6. Disconnect the intake air duct.
7. Disconnect the coolant lines from the throttle body.
8. Remove the bolts from the common chamber.
9. Remove the throttle body from the common chamber.

10. Remove the gasket from the common chamber.
11. Remove the TP sensor. Refer to Throttle Position (TP) Sensor in this section.

INSTALLATION PROCEDURE

1. Install the TP sensor. Refer to Throttle Position (TP) Sensor in this section.
2. Install the gasket on the common chamber.
3. Install the throttle body on the common chamber.