Connecting Rod: Specifications
Connecting Rod Thrust Clearance

Use a feeler gauge to measure the thrust clearance at the large end of the connecting rod. If the clearance exceeds the specified limit, the connecting rod
must be replaced. 

Standard ...................................................................................................................................................  0.16 mm - 0.35 mm (0.0063 inch - 0.0138 inch) 
Limit .................................................................................................................................................................................................  0.40 mm (0.0157 inch)