isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Cylinder Head Cover LH|Page 1429 > < Valve Cover|Specifications
Page 1
background image

Valve Cover: Service and Repair
Cylinder Head Cover LH

REMOVAL 

1. Disconnect battery ground cable.
2. Drain engine coolant from faucet bottom of radiator.

3. Remove engine cover from the dowels on the common chamber.

4. Remove air cleaner duct assembly (3) and air cleaner element (4).

NOTE:  Disconnect the Mass Air Flow (MAF) sensor connector, Intake Air Temperature (IAT) sensor connector, and Positive Crankcase
Ventilation (PCV) hose before hand the air cleaner duct assembly is removed.

5. Disconnect following wiring connectors and bonding cable:

-

Manifold Absolute Pressure (MAP) sensor

-

Vacuum Switching Valve (VSV) for Induction Air Control Valve (IACV) actuator

-

Ignition coils for left bank

-

Fuel injectors for left bank

-

Idle Air Control (IAC) valve

-

Throttle Position Sensor (TPS)

-

Bonding cable

-

Others as necessitated

6. Disconnect following vacuum hoses:

-

Brake master VAC

-

Canister

-

VSV for IACV actuator

-

Duty solenoid valve

Cylinder Head Cover LH|Page 1429 > < Valve Cover|Specifications