Air Cleaner Housing: Service and Repair

REMOVAL 

1. Remove positive ventilation hose connector (1).
2. Remove intake air temperature sensor (2).
3. Remove air flow sensor (3).
4. Remove air cleaner duct assembly (4).
5. Remove air cleaner element (5).

INSPECTION 

Check the air cleaner filter for damage or dust clogging.
Replace if it is damaged, or clean if it is clogged.

Cleaning Method 
Tap the air cleaner filter gently so as not to damage the paper filter, or clean the element by blowing with compressed air of about 490 kPa (71 psi)
from the clean side if it is extremely dirty.