isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 5523 > < Leak Check - Repair of Refrigerant Leaks|Page 5521
Page 10
background image

Inspection steps

Check the components of the air conditioner to see if there occurs any refrigerant leak along the flow of refrigerant.

NOTE:

-

To avoid an error in the detection of refrigerant leak, make sure there is no refrigerant vapor or cigarette smoke around the vehicle before
conducting the inspection.
Also, select a location where the refrigerant vapor will not be blown off by wind.

-

Inspection should be conducted chiefly on the pipe connections and sections where a marked oil contamination is found.
When refrigerant is leaking, oil inside is also leaking at the same time.

-

It is not possible to visually check the leak from inside the cooling unit. Follow the method below when checking.
Remove the drain hose or resistor of the cooling unit, and insert a leak detector to see if there occurs any leak.

High pressure side

1. Discharger section of compressor
2. Inlet/outlet section of condenser
3. Inlet/outlet section of receiver driver
4. Inlet section of cooling unit

Low pressure side

1. Outlet section of cooling unit
2. Intake section of compressor

Major checking points of refrigerant leak Compressor

-

Pipe connection

-

Sealing section of shaft

-

Mating section of cylinder

Condenser

-

Pipe connection

-

Welds of condenser body

Receiver drier

-

Pipe connection

-

Attaching section of pressure switch 

-

Section around the sight glass 

Evaporator unit (cooling unit)

-

Pipe connection

-

Connections of expansion valve

-

Brazed sections of evaporator

NOTE:  The evaporator and expansion valve are contained in the case. Remove the drain hose or the resistor of the cooling unit and insert a leak
detector when checking for any leak.

Flexible hose

-

Pipe connection

-

Caulking section of the hose

-

Hose (cracks, pinholes, flaws)

Pipe

-

Pipe connection

-

Pipe (cracks, flaws)

Charge Valve

NOTE:  The charge valve, which is used to connect the gauge manifold, is normally provided with a resin cap. When the valve inside gets deteriorated, 
refrigerant will leak out.

Leak at Refrigerant Line Connections

1. Check the torque on the refrigerant line fitting and, if too loose, tighten to the specified torque.

-

Use two wrenches to prevent twisting and damage to the line.

-

Do not over tighten.

2. Perform a leak test on the refrigerant line fitting.
3. If the leak is still present, discharge and recover the refrigerant from the system.

Leak Check - Repair of Refrigerant Leaks|Page 5523 > < Leak Check - Repair of Refrigerant Leaks|Page 5521