isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 6662 > < Diagram Information and Instructions|Page 6660
Page 2
background image

1. With the battery connected, Remove the blown fuse.
2. Connect the short finder between the positive battery terminal and the load side fuse terminal.
3. Close all switches in series with the wire you are troubleshooting.
4. Turn ON the short finder. It sends pulses of current to the short. This creates a pulsing magnetic field around the wiring between the fuse box and

the short.

5. Beginning at the fuse box, slowly move the short finder meter along the circuit wiring. The meter will show current pulses through sheet metal and

body trim. As long as the meter is between the fuse and the short, the needle will move with each current pulse. Once you move the meter past the
point of the short, the needle will stop moving. Check around this area to locate the cause of the short circuit.

Testing For A Short to Ground With A Test Light or Voltmeter