isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 1063 > < Leak Check - Repair of Refrigerant Leaks|Page 1061
Page 9
background image

damaged.

When connecting the refrigerant line at a block joint, securely insert the projecting portion of the joint portion into the connecting hole on the unit side
and secure with a bolt. Apply specified compressor oil to the O-rings prior to connecting.

CAUTION:  Compressor (PAG) oil to be used varies according to compressor model. Be sure to apply oil specified for the model of compressor.

O-rings must be closely aligned with raised portion of refrigerant line.
Insert nut into union. 
First tighten nut by hand as much as possible, then tighten nut to specified torque.

Leak Check
Inspection of refrigerant leak

Refrigerant leak may cause an adverse effect not only on the performance and durability of each component of the air-conditioner, but also on the global
atmosphere.

Therefore, it is most important to repair refrigerant leak when there is any leak found.

Inspection flow of refrigerant leak

Leak Check - Repair of Refrigerant Leaks|Page 1063 > < Leak Check - Repair of Refrigerant Leaks|Page 1061