Canister Purge Solenoid: Service and Repair

Removal Procedure 

1. Disconnect the electrical connector from the EVAP canister purge solenoid.

2. Disconnect the vacuum hoses from the EVAP canister purge solenoid.
3. Remove the EVAP canister purge solenoid retaining bolt from the upper intake manifold.

4. Remove the EVAP canister purge solenoid.

Installation Procedure 

1. Install the EVAP canister purge solenoid on the upper intake manifold.
2. Install the EVAP canister purge solenoid retaining bolt.
3. Connect the vacuum hoses to the EVAP canister purge solenoid.
4. Connect the electrical connector to the EVAP canister purge solenoid.