isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

EGR Valve Pintle Position Sensor <--> [EGR Valve Position Sensor] > < Linear Exhaust Gas Recirculation (EGR) Valve <--> [EGR Valve]|Specifications|Page 2677
Page 1
background image

Linear Exhaust Gas Recirculation (EGR) Valve: Service and Repair

Removal Procedure 

1. Disconnect the negative battery cable.

2. Disconnect the electrical connector at the EGR valve.

3. Remove the bolt and the nut from the upper intake manifold.
4. Remove the EGR valve from the upper intake manifold.
5. Remove the gasket from the upper intake manifold.

Installation Procedure 

1. Install the gasket on the upper intake manifold.
2. Install the EGR valve on the upper intake manifold.
3. Secure the EGR valve and the gasket with the bolt and the nut.

NOTE:  It is possible to install the EGR valve rotated 180° from the correct position. Make sure that the base of the valve is placed so that it
aligns with the mounting flange.

4. Connect the electrical connector at the EGR valve.
5. Connect the negative battery cable.

EGR Valve Pintle Position Sensor <--> [EGR Valve Position Sensor] > < Linear Exhaust Gas Recirculation (EGR) Valve <--> [EGR Valve]|Specifications|Page 2677