Positive Crankcase Ventilation Valve: Service and Repair

Removal Procedure 

1. Remove the vacuum hose at the PCV valve.

-

Slide the clamp back to release the hose.

2. Pull the PCV valve from the rubber grommet in the right valve cover.

Installation Procedure 

1. Push the PCV valve into the rubber grommet in the left valve cover.
2. Install the vacuum hose on the PCV valve and secure the vacuum hose with the clamp.