isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 448 > < Diagram Information and Instructions|Page 446
Page 3
background image

1.  Remove the blown fuse and disconnect the load.
2.  Connect a test light or voltmeter across the fuse terminals. Make sure voltage is being applied to the battery side fuse terminal. Check schematic to

see if the ignition switch needs to be in RUN.

3.  Beginning near the fuse box, wiggle the harness. Continue this at convenient points about six inches apart while watching the test light or

voltmeter.

4.  When the test light blinks or the voltmeter needle moves, there is a short to ground in the wiring near that point.

Testing For A Short to Gnd w/ Self-Powered Light or Ohm Meter

1.  Remove the blown fuse and disconnect the battery and load.
2.  Connect one lead of a self-powered test light or ohmmeter to the fuse terminal load side.
3.  Connect the other lead to a known good ground.
4.  Beginning near the fuse box, wiggle the harness. Continue this at convenient points about six inches apart while watching the test light or

ohmmeter.

5.  If the self-powered test light blinks or the ohmmeter needle moves, there is a short to ground in the wiring near that point.

Testing For Voltage Drop

Diagram Information and Instructions|Page 448 > < Diagram Information and Instructions|Page 446