isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Control Assembly, HVAC > < Condenser HVAC|Specifications
Page 1
background image

Condenser HVAC: Service and Repair

Preparation:

Disconnect the battery ground cable. Discharge and recover refrigerant (Refer to "REFRIGERANT RECOVERY".)

1.  Radiator grille
2.  Front bumper assembly
3.  Engine hood front end stay
4.  Pressure switch connector
5.  Refrigerant line

When removing the line connector, the connecting part should immediately be plugged or capped to prevent foreign matter from being mixed
into the line.

6.  Condenser assembly

INSTALLATION

6.  Condenser assembly

If installing a new condenser, be sure to add 3O cc (1.0 fl.oz.) of new compressor oil to a new one.

Tighten the condenser fixing bolts to the specified torque.
Torque: N.m (lb.in) = 6 (52)

5.  Refrigerant line

Tighten the inlet line connector fixing bolt to the specified torque.
Torque: N.m (lb.in) = 15 (11)

Tighten the outlet line connector fixing bolt to the specified torque.
Torque: N.m (lb.in) = 6 (52)

O-rings cannot be reused. Always replace with new ones.

Be sure to apply new compressor oil to the O-rings when connecting refrigerant line.

4.  Pressure switch connector
3.  Engine hood front end stay
2.  Front bumper assembly
1.  Radiator grille

Control Assembly, HVAC > < Condenser HVAC|Specifications