isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 5460 > < Leak Check - Repair of Refrigerant Leaks|Page 5458
Page 6
background image

Direct charging with a weight scale charging station method

1.  Make sure the evacuation process is correctly completed.
2.  Connect the center hose of the manifold gauge to the weight scale.
3.  Connect the low pressure charging hose of the manifold gauge to the low pressure side service valve of the vehicle.
4.  Connect the high pressure charging hose of the manifold gauge to the high pressure side service valve of the vehicle.
5.  Place the refrigerant container up right on a weight scale.

Note the total weight before charging the refrigerant.

5a.  Open refrigerant container valve.
5b.  Open low side valve on the manifold gauge set. Refer to the manufacturer's instruction's for a weight scale charging station.

6.  Perform system leak test.

Charge the system with approx. 200 g (0.44 lbs) of HFC-134a.

Make sure the high pressure valve of the manifold gauge is closed.

Check to ensure that the degree of pressure does not change.

Check for refrigerant leaks by using a HFC134a leak detector.

If a leak occurs, recover the refrigerant. Repair the leak, and start all over again from the first step of evacuation.

7.  If no leaks are found, continue charging refrigerant to the air conditioning system.

Charge the refrigerant until the scale reading decreases by the amount of the charge specified.

Specified amount g (lbs.) = 750 (1.65)

If charging the system becomes difficult:
1.  Run the engine at idle and close all the vehicle doors.
2.  Turn A/C switch "ON".
3.  Set the fan switch to its highest position.
4.  Set air source selector lever to "CIRC".
5.  Slowly open the low side valve on the manifold gauge set.

WARNING:  BE ABSOLUTELY SURE NOT TO OPEN THE HIGH PRESSURE VALVE OF THE MANIFOLD GAUGE. SHOULD
THE HIGH PRESSURE VALVE BE OPENED, THE HIGH PRESSURE REFRIGERANT WOULD FLOW BACKWARD, AND THIS
MAY CAUSE THE REFRIGERANT CONTAINER TO BURST.

8.  When finished with the refrigerant charging, close the low pressure valve of the manifold gauge and container valve.
9.  Check for refrigerant leaks.

Checking the A/C system

1.  Run the engine and close all the vehicle doors.
2.  Turn A/C switch "ON", set the fan switch to its highest position, set air source lever to "CIRC" and set temperature lever to full cool position.
3.  Check the high and low pressure of the manifold gauge.

Immediately after charging refrigerant, both high and low pressure might be slightly high, but they settle down to the pressure guide- lines
shown below:
Ambient temperature: 25-30°C (77 - 86°F) Pressure guidelines:

High-pressure side;
Approx. 1372.9-1863.3 kPa (199.1-270.2 psi)

Low-pressure side;
Approx. 147.1-294.2 kPa (21.3-42.7 psi) 

If an abnormal pressure is found, refer to "CHECKING REFRIGERANT SYSTEM WITH MANIFOLD GAUGE".

4.  Put your hand in front of the air outlet and move the temperature control lever of the control panel to different positions. Check if the outlet

temperature changes as selected by the control knob.

3.  Charging

Precautions for Replacement or Repair of Air Conditioning Parts

Leak Check - Repair of Refrigerant Leaks|Page 5460 > < Leak Check - Repair of Refrigerant Leaks|Page 5458