isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Fuel Meter Body > < Fuel Line Coupler|Service Precautions|Page 2673
Page 3
background image

NOTE:  The retainer, once removed from the pipe, cannot be reused. Just replace with a new retainer. Insert the new retainer into the connector
side until it clicks, and connect the pipe as inserting it into the retainer until it clicks.

(Return Pipe)

-

Replace the pipe and connector if scratch, dent or crack is found.

-

Remove mud or dust from the pipe and make sure that the end including spool is free from defects, such as scratch, rust, and dent, which may
cause poor sealability. If defective, replace with a new pipe.

-

After cleaning the pipe, insert it straight into the connector until it clicks. After it clicks, try pulling it out to make sure that it is not drawn and is
securely locked.