9. Remove evaporator core.

10. Remove expansion valve.

-

Tear off the insulator carefully.

-

Remove the sensor fixing clip.

-

Use a back-up wrench when disconnecting all refrigerant pipes.

INSTALLATION

To install, follow the removal steps in the reverse order, noting the following points:

1. The sensor is installed on the core with the clip.
2. The sensor must not interfere with the evaporator core.

3. When installing the new evaporator core, install the thermo sensor (2) to the evaporator core (1) specified position with the clip in the illustration.

4. O-rings cannot be reused. Always replace with new ones.
5. Be sure to apply new compressor oil to the O-rings when connecting lines.
6. Be sure to install the sensor and the insulator on the place where they were before.
7. To install a new evaporator core, add 50 cc (1.7 fl. oz.) of new compressor oil to the new core.
8. Tighten the refrigerant lines to the specified torque. Refer to Specifications for Torque Specifications.
9. Apply an adhesive to the parting face of the lining when assembling the evaporator assembly