isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Condenser Fan > < Condenser HVAC|Locations|Page 3807
Page 2
background image

1. Install condenser assembly.

-

If installing a new condenser, be sure to add 30 cc (1.0 fl oz) of new compressor oil to a new one.

-

Tighten the condenser fixing bolts to the specified torque.
Torque: 6 Nm (52 lb in)

2. Connect refrigerant line.

-

Tighten the inlet line connector fixing bolt to the specified torque.
Torque: 15 Nm (11 lb ft)

-

Tighten the outlet line connector fixing bolt to the specified torque.
Torque: 6 Nm (52 lb in)

-

O-rings cannot be reused. Always replace with new ones.

-

Be sure to apply new compressor oil to the O-rings when connecting the refrigerant line.

3. Connect pressure switch connector.
4. Install engine hood front end stay.
5. Install front bumper lower center.
6. Install front bumper assembly.
7. Install front turn signal light.
8. Install radiator grille.