jaguar Workshop Repair Guides

Jaguar Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3809 > < Initial Inspection and Diagnostic Overview|Page 3807
Page 4
background image

G195523t69 : CHECK EPB MODULE FOR DAMAGE

1. Disconnect the EPB module electrical connector CA242.
2. INSPECT the EPB module for damage.

-

Does the EPB module indicate any signs of damage?

-> Yes

INSTALL a new EPB module. CLEAR the DTC. TEST the system for normal operation.

-> No

G195523t70 : CHECK THE SCP + FOR SHORT CIRCUIT TO GROUND

1. Turn the ignition switch to the OFF position.
2. Disconnect the battery negative terminal.
3. Measure the resistance between the diagnostic connector FC001 pin 2, (Y) and GROUND.

-

Is the resistance less than 5 ohms?

-> Yes

REPAIR the SCP + circuit. CLEAR the DTC. TEST the system for normal operation.

-> No

G195523t71 : CHECK THE SCP + FOR SHORT CIRCUIT TO BATTERY

1. Turn the ignition switch to the OFF position.
2. Disconnect the battery negative terminal.
3. Measure the resistance between the diagnostic connector FC001 pin 2, (Y) and pin 016, BATTERY.

-

Is the resistance less than 5 ohms?

-> Yes

REPAIR the SCP + circuit. CLEAR the DTC. TEST the system for normal operation.

-> No

G195523t72 : CHECK THE SCP - FOR SHORT CIRCUIT TO GROUND

1. Turn the ignition switch to the OFF position.
2. Disconnect the battery negative terminal.
3. Measure the resistance between the diagnostic connector FC001 pin 10, (U) and GROUND.

-

Is the resistance less than 5 ohms?

-> Yes

REPAIR the SCP - circuit. CLEAR the DTC. TEST the system for normal operation.

-> No

G195523t73 : CHECK THE SCP - FOR SHORT CIRCUIT TO BATTERY

1. Turn the ignition switch to the OFF position.
2. Disconnect the battery negative terminal.
3. Measure the resistance between the diagnostic connector FC001 pin 10, (U) and pin 016, BATTERY (OY).

-

Is the resistance less than 5 ohms?

-> Yes

REPAIR the SCP - circuit. CLEAR the DTC. TEST the system for normal operation.

-> No

G195523t74 : CHECK FOR SHORT CIRCUIT BETWEEN SCP + AND SCP -

Initial Inspection and Diagnostic Overview|Page 3809 > < Initial Inspection and Diagnostic Overview|Page 3807