XJR (X300) L6-4.0L SC (AJ16) (1995)
Use only approved recovery equipment
It is illegal to vent refrigerant to the atmosphere.
SERVICE PORT LOCATIONS - ALL 1995 MY SEDAN RANGE VEHICLES
HIGH SIDE PORT
Low SIDE PORT
SEDAN (4.0L)
Compressor outlet pipe - Right side of
Compressor intake pipe - Right side of
RANGE
engine cooling fan duct
engine compartment near bulkhead
XJ12
Compressor outlet flange
Compressor intake pipe - Right side of
engine near timing cover
^
Torque the pressure cutout switches to 3.5 - 6 lb ft (5 - 8 Nm). Do not exceed 6 lb ft
WARNING:
DO NOT EXCEED 6 lb ft (8 Nm) TORQUE WHEN TIGHTENING PRESSURE CUTOUT SWITCHES. Overtightening will result in failure of the
Schrader valve causing liquid refrigerant to be discharged when the switch is removed.
VIN 720580 ON - SCHRADER VALVES
^
It is not necessary to depressurize the system on these vehicles when removing the dual (binary) or triple (trinary) pressure cutout switches.
^
Torque the pressure cutout switches to 3.5 - 6 lb ft (5 - 8 Nm). Do not exceed 6 lb ft