Fit two bolts to sandwich plate / valve body for alignment purposes, see Fig. 1.

Note:  Select the close fitting bolt hole of the valve body and the elongated hole of the sandwich plate.

^

Fit new accumulator block to sandwich plate gasket.

^

Fit springs to accumulator block pistons.

^

Fit and align accumulator block, pistons and springs assembly to valve body sandwich plate.

^

Depress accumulator assembly against spring pressure.

^

Fit and tighten accumulator block to valve body securing bolts.

^

Remove the two bolts from sandwich plate / valve body (used for alignment purposes).

^

Invert valve body assembly.

^

Connect internal harness plug to variable force motor.

^

Connect internal harness plug to pulse width modulator.

^

Connect internal harness plug to temperature sensor.

^

Connect internal harness plug to 'B' shift solenoid.

^

Connect internal harness plug to 'A' shift solenoid.