Amanti V6-3.8L (2007)
4. Install the drain plug via the gasket, and tighten it to the specified torque.
TORQUE : 40 - 50 Nm (4 - 5 kgf.m, 29 - 36 lb-ft)
5. Pour the new fluid in through the oil filler tube.
CAUTION
Stop pouring if the full volume of fluid cannot be poured in.
6. Repeat the procedure in step (2).
NOTE
Check the old fluid for contamination. If it has been contaminated, repeat the steps (5) and (6).
7. Pour the new fluid in through the oil filler tube.
8. Reconnect the hose which was disconnected in step (1) above and firmly replace the oil level gauge.(In case of this "replace", this means after
wiping off any dirt around the oil level gauge, insert it into the filler tube.)
9. Start the engine and run it at idle for 1-2 minutes.
10. Move the select lever through all positions, and then move it to the "N" position.
11. Drive the vehicle until the fluid temperature rises to the normal temperature [70-80°C (158-176°F)], and then check the fluid level again. The fluid
level must be at the 75°C (167°F) mark.
12. Firmly insert the oil level gauge into the oil filler tube.