Borrego 4WD V6-3.8L (2009)
Variable Valve Timing Actuator: Service and Repair
Removal
[CVVT Oil Control Valve (Intake)]
1. Turn ignition switch OFF and disconnect the negative (-) battery cable.
2. Remove the intake manifold .
3. Disconnect the CVVT oil control valve connector (A).
4. Remove the mounting bolt (B), and then remove the valve from the engine.
[CVVT Oil Control Valve (Exhaust)]
1. Turn ignition switch OFF and disconnect the negative (-) battery cable.
2. Disconnect the CVVT oil control valve connector (A).
3. Remove the cylinder head cover .
4. Remove the mounting bolt (A), and then remove the valve from the engine.
Installation
1. Installation is reverse of removal.
CVVT oil control valve installation bolt:
9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lbf.ft)
CAUTION:
Pay attention to color of the valve connector (Component and harness side) when installing. If an OCV is installed on opposite bank, the engine
may be damaged.
[Connector Color]