Battery: Testing and Inspection
Battery Test Procedure

Battery Test Procedure

1. Connect the tester to the battery.

A. Red clamp to battery positive (+) terminal.
B. Black clamp to battery negative (-) terminal.

CAUTION:
Connect clamps securely. If "CHECK CONNECTION" message is displayed on the screen, reconnect clamps securely.

2. The tester will ask if the battery is connected "IN A VEHICLE" or "OUT OF A VEHICLE". Make your selection by pressing the arrow buttons;

then press ENTER.

3. Choose either CCA or CCP and press the ENTER button.

NOTE:
-

CCA : Cold cranking amps, is an SAE specification for cranking batteries at -18°C (0°F).

-

CCP : Cold cranking amps, is an SAE specification for korean manufacturer's for cranking batteries at -18°C (0°F).

4. Set the CCA value displayed on the screen to the CCA value marked on the battery label by pressing up and down buttons and press ENTER.