8. Ignition key reminder

Time specification 
T1 : 0.5 sec.
T2 : 0 - 0.5 sec.

9. Outside door key illumination (without burglar alarm)

Time specification 
T1 : 10 ± 1.0 sec.

10. Power window timer

Time specification 
T1 :30 ± 5 sec.

11. Central door lock/unlock (without burglar alarm)

Time specification 
T : 0.5 ± 0.1 sec.

12. Central door lock/unlock (with burglar alarm)