9. DEFOGGER TIMER (INCLUDING OUTSIDE MIRROR HEATER)

1. Once ALT *L* is ON, if the defogger is switched ON, the defogger will stay ON for 20 minutes duration.
2. If defogger switch is pressed again (see Step 1 ), or if ignition is switched OFF, the defogger will shut OFF.

10. POWER WINDOW TIMER

1. When the ignition is switched OFF, power window output remains ON for 30 seconds and then turns OFF.
2. Related to Step 1), if the driver door or assist door is opened, window power output is turned OFF immediately.
3. When the driver door or assist door is opened, the power window relay output is turned OFF immediately.

11. TX LOCK TWICE ALARM

In the state that the door is Locked by TX (alarm state), if TX Lock signal is received again within 4 sec after the last TX Lock signal is received,
Horn shall be output at one time (0.05 sec)