kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Battery Test Procedure|Page 5094 > < Battery Test Procedure
Page 2
background image

2. The tester will ask if the battery is connected "IN A VEHICLE" or "OUT OF A VEHICLE". Make your selection by pressing the arrow buttons;

then press ENTER.

3. Choose either CCA or CCP and press the ENTER button.

NOTE
-

CCA : Cold cranking amps, is an SAE specification for cranking batteried at OFF (-18 degrees C).

-

CCP : Cold cranking amps, is an SAE specification for korean manufacturer's for cranking batteried at 0 degrees F (-18 degrees C)

4. Set the CCA value displayed on the screen to the CCA value marked on the battery label by pressing up and down buttons and press ENTER.

NOTE:  The battery ratings(CCA) displayed on the tester must be identical to the ratings marked on battery label.

5. The tester (Micro570) displays battery test results including voltage and battery ratings.

A relevant action must be given according to the test results by referring to the battery test results as shown in the table.

NOTE:  The battery ratings(CCA) displayed on the tester must be identical to the ratings marked on battery label.

6. To conduct starter test, continuously, press ENTER.

Battery Test Procedure|Page 5094 > < Battery Test Procedure