kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 7855 > < Diagram Information and Instructions|Page 7853
Page 9
background image

If an open circuit occurs (as seen in (FIG. 1)), it can be found by performing Step 2 (Continuity Check Method) or Step 3 (Voltage Check
Method).

2. Continuity Check Method

NOTE:  When measuring for resistance, lightly shake the wire harness above and below or from side to side.

Specification (Resistance)
1 Ohm
 or less -> Normal Circuit
1 MOhm or Higher -> Open Circuit

a. Disconnect connectors (A), (C) and measure resistance between connector (A), and (C) as shown in [FIG. 2].

In [FIG. 2.] the measured resistance of line 1 and 2 is higher than 1 MOhm and below 1 Ohm respectively. Specifically the open circuit is line
1 (Line 2 is normal) To find exact break point. Check sub line of line 1 as described in next step.

b. Disconnect connector (B), and measure for resistance between connector (C) and (B1) and between (B2). and (A) as shown in [FIG. 3].

In this case the measured resistance between connector (C) and (B1) is higher than 1 MOhm and the open circuit is between terminal 1 of
connector (C) and terminal 1 of connector (B1).

Diagram Information and Instructions|Page 7855 > < Diagram Information and Instructions|Page 7853