Rondo L4-2.4L (2007)
b. In case of abnormal contact pressure, replace the female terminal.
WIRE HARNESS INSPECTION PROCEDURE
1. Before removing the wire harness, check the wire harness position and crimping in order to restore it correctly.
2. Check whether the wire harness is twisted, pulled or loosened.
3. Check whether the temperature of the wire harness is abnormally high.
4. Check whether the wire harness is rotating, moving or vibrating against the sharp edge of a part.
5. Check the connection between the wire harness and any installed part.
6. If the covering of wire harness is damaged; secure, repair or replace the harness.
ELECTRICAL CIRCUIT INSPECTION PROCEDURE
CHECK OPEN CIRCUIT
1. Procedures for Open Circuit
-
Continuity Check
-
Voltage Check
If an open circuit occurs (as seen in [FIG. 1]), it can be found by performing Step 2 (Continuity Check Method) or Step 3 (Voltage Check Method)
as mentioned as.
2. Continuity Check Method
NOTE: When measuring for resistance, lightly shake the wire harness above and below or from side to side.
Specification (Resistance)
1 ohm or less Normal Circuit
1 Mohm or Higher Open Circuit
a. Disconnect connectors (A), (C) and measure resistance between connector (A) and (C) as shown in [FIG. 2].
In [FIG.2.] the measured resistance of line 1 and 2 is higher than 1 Mohm and below 1 ohm respectively. Specifically the open circuit is line
1 (Line 2 is normal). To find exact break point, check sub line of line 1 as described in next step.