Sephia GS Sedan L4-1.8L (1997)
1.
Discharge the A/C system.
* NOTICE
Refer to your refrigerant recovery station operating instructions for proper recovery procedures.
2.
Remove the nut attaching the suction hose to the evaporator outlet line fitting.
3.
Remove the bolt attaching the suction hose to the A/C compressor manifold, then remove and discard the suction hose.
4.
Remove the bolt attaching the discharge hose to the A/C compressor manifold and temporarily position the discharge hose away from the A/C
compressor.