19. Connect the wiring over the surge tank.

1) Connect the injection harness connector(A)
2) Connect the camshaft position sensor(CMP) harness connector(B).
3) Connect the ground lines(C).
4) Connect the ignition coil harness connector(D).
5) Connect the condensor connector(E).
6) Connect the variable induction system(VIS) solenoid valve connector(G).
7) Connect the oil control valve(OCV) harness connector(F).

20. Connect the other breather hose(A), the Positive Crankcase Ventilation (PCV) hose(C) and the Electronic Throttle Control(ETC) cooling

hoses(D), ETC connector(E).